Mean Well LED Driver HLN-60H Series 60W 12V – 54V

Mean Well LED Driver HLN-60H Series 60W 12V – 54V

Be the first to review this product

Quick Overview

Built-in 3 in 1 dimming function (1-10VDC, PWM signal, or resistance)

    Built-in constant current limiting circuit (C.V. + C.C mode)

    Protections: Short circuit/ Over current/ Over voltage/ Over temperature

    Other features:

    • Universal AC input (up to 305VAC) / Full range
    • Fully isolated plastic case with IP64 level
    • Class 2 power unit
    • High efficiency up to 91%
    • Cooling by free air convection
    • Suitable for dry, damp locations
    • Suitable for LED lighting and moving sign applications
    • Built-in active PFC function, PF> 0.9 for 60% load or higher
    • 3 years warranty

    Call-Us

    * Required Fields

    TND10.00

    Technical Specifications

    HLN-60H-15BHLN-60H-48AHLN-60H-42AHLN-60H-36AHLN-60H-30AHLN-60H-24AHLN-60H-20AHLN-60H-54AHLN-60H-48BHLN-60H-42BHLN-60H-36BHLN-60H-30BHLN-60H-24BHLN-60H-20BHLN-60H-15AHLN-60H-54B
    Wattage 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
    Input Voltage (V) 90~305VAC; 127~431VDC 90~305VAC; 127~431VDC 90~305VAC; 127~431VDC 90~305VAC; 127~431VDC 90~305VAC; 127~431VDC 90~305VAC; 127~431VDC 90~305VAC; 127~431VDC 90~305VAC; 127~431VDC 90~305VAC; 127~431VDC 90~305VAC; 127~431VDC 90~305VAC; 127~431VDC 90~305VAC; 127~431VDC 90~305VAC; 127~431VDC 90~305VAC; 127~431VDC 90~305VAC; 127~431VDC 90~305VAC; 127~431VDC
    Output Current (A) 0~4.0 0~1.30 0~1.45 0~1.70 0~2.0 0~2.5 0~3.0 0~1.15 0~41.30 0~1.45 0~1.70 0~2.0 0~2.5 0~3.0 0~4.0 0~1.15
    Output Voltage (V) 15 48 42 36 30 24 20 54 48 42 36 30 24 20 15 54
    Output Voltage Options Single Single Single Single Single Single Single Single Single Single Single Single Single Single Single Single
    DC output adjustment +/-10% rated output voltage +/-10% rated output voltage +/-10% rated output voltage +/-10% rated output voltage +/-10% rated output voltage +/-10% rated output voltage +/-10% rated output voltage +/-10% rated output voltage +/-10% rated output voltage +/-10% rated output voltage +/-10% rated output voltage +/-10% rated output voltage +/-10% rated output voltage +/-10% rated output voltage +/-10% rated output voltage +/-10% rated output voltage
    Working Temperature -40~+50°C (refer to output derating curve) -40~+70°C -40~+70°C -40~+70°C -40~+70°C -40~+50°C (refer to output derating curve) -40~+50°C (refer to output derating curve) -40~+70°C -40~+70°C -40~+70°C -40~+70°C -40~+70°C -40~+70°C -40~+50°C (refer to output derating curve) -40~+50°C (refer to output derating curve) -40~+70°C
    Safety Standards UL8750, TUV EN61347-1, EN61347-2-13 approved; Design refer to UL/EN60950-1, EN60335-1, UL8750, TUV EN61347-1, ENG1347-2-13, PSE J61347-1 UL8750, TUV EN61347-1, EN61347-2-13 approved; Design refer to UL/EN60950-1, EN60335-1, UL8750, TUV EN61347-1, ENG1347-2-13, PSE J61347-1 UL8750, TUV EN61347-1, EN61347-2-13 approved; Design refer to UL/EN60950-1, EN60335-1, UL8750, TUV EN61347-1, ENG1347-2-13, PSE J61347-1 UL8750, TUV EN61347-1, EN61347-2-13 approved; Design refer to UL/EN60950-1, EN60335-1, UL8750, TUV EN61347-1, ENG1347-2-13, PSE J61347-1 UL8750, TUV EN61347-1, EN61347-2-13 approved; Design refer to UL/EN60950-1, EN60335-1, UL8750, TUV EN61347-1, ENG1347-2-13, PSE J61347-1 UL8750, TUV EN61347-1, EN61347-2-13 approved; Design refer to UL/EN60950-1, EN60335-1, UL8750, TUV EN61347-1, ENG1347-2-13, PSE J61347-1 UL8750, TUV EN61347-1, EN61347-2-13 approved; Design refer to UL/EN60950-1, EN60335-1, UL8750, TUV EN61347-1, ENG1347-2-13, PSE J61347-1 UL8750, TUV EN61347-1, EN61347-2-13 approved; Design refer to UL/EN60950-1, EN60335-1, UL8750, TUV EN61347-1, ENG1347-2-13, PSE J61347-1 UL8750, TUV EN61347-1, EN61347-2-13 approved; Design refer to UL/EN60950-1, EN60335-1, UL8750, TUV EN61347-1, ENG1347-2-13, PSE J61347-1 UL8750, TUV EN61347-1, EN61347-2-13 approved; Design refer to UL/EN60950-1, EN60335-1, UL8750, TUV EN61347-1, ENG1347-2-13, PSE J61347-1 UL8750, TUV EN61347-1, EN61347-2-13 approved; Design refer to UL/EN60950-1, EN60335-1, UL8750, TUV EN61347-1, ENG1347-2-13, PSE J61347-1 UL8750, TUV EN61347-1, EN61347-2-13 approved; Design refer to UL/EN60950-1, EN60335-1, UL8750, TUV EN61347-1, ENG1347-2-13, PSE J61347-1 UL8750, TUV EN61347-1, EN61347-2-13 approved; Design refer to UL/EN60950-1, EN60335-1, UL8750, TUV EN61347-1, ENG1347-2-13, PSE J61347-1 UL8750, TUV EN61347-1, EN61347-2-13 approved; Design refer to UL/EN60950-1, EN60335-1, UL8750, TUV EN61347-1, ENG1347-2-13, PSE J61347-1 UL8750, TUV EN61347-1, EN61347-2-13 approved; Design refer to UL/EN60950-1, EN60335-1, UL8750, TUV EN61347-1, ENG1347-2-13, PSE J61347-1 UL8750, TUV EN61347-1, EN61347-2-13 approved; Design refer to UL/EN60950-1, EN60335-1, UL8750, TUV EN61347-1, ENG1347-2-13, PSE J61347-1
    EMC Standards EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024 EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024 EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024 EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024 EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024 EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024 EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024 EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024 EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024 EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024 EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024 EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024 EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024 EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024 EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024 EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024
    Packaging 32pcs/12.2KG 32pcs/12.2KG 32pcs/12.2KG 32pcs/12.2KG 32pcs/12.2KG 32pcs/12.2KG 32pcs/12.2KG 32pcs/12.2KG 32pcs/12.2KG 32pcs/12.2KG 32pcs/12.2KG 32pcs/12.2KG 32pcs/12.2KG 32pcs/12.2KG 32pcs/12.2KG 32pcs/12.2KG
    RS Part No. 738-1769 738-2201 738-2208 738-2198 738-2194 738-2191 738-2182 738-2205 738-1781 738-1788 738-1779 738-1775 738-1772 738-1763 738-2188 738-2205

    Technical Specification

    Download PDF Datasheet Mean Well LED Driver HLN-60H Series 60W 12V – 54V Specifications PDF
    Wattage 60
    Input Voltage (V) 90~305VAC; 127~431VDC
    Output Current (A) 0~1.15
    Output Voltage (V) 54
    Output Voltage Options Single
    DC output adjustment +/-10% rated output voltage
    Working Temperature -40~+70°C
    Safety Standards UL8750, TUV EN61347-1, EN61347-2-13 approved; Design refer to UL/EN60950-1, EN60335-1, UL8750, TUV EN61347-1, ENG1347-2-13, PSE J61347-1
    EMC Standards EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024
    Packaging 32pcs/12.2KG
    RS Part No. 738-2205

    Write Your Own Review