Technical Specifications

HLG-60H-15AHLG-60H-15BHLG-60H-54AHLG-60H-48AHLG-60H-42AHLG-60H-20AHLG-60H-36AHLG-60H-30AHLG-60H-24AHLG-60H-54BHLG-60H-48BHLG-60H-42BHLG-60H-36BHLG-60H-30BHLG-60H-24BHLG-60H-20BHLG-60H-C350BHLG-60H-C350AHLG-60H-C700BHLG-60H-C700A
Wattage 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 70 70 70 70
Input Voltage (V) 90~305VAC, 127~431VDC 90~305VAC, 127~431VDC 90~305VAC, 127~431VDC 90~305VAC, 127~431VDC 90~305VAC, 127~431VDC 90~305VAC, 127~431VDC 90~305VAC, 127~431VDC 90~305VAC, 127~431VDC 90~305VAC, 127~431VDC 90~305VAC, 127~431VDC 90~305VAC, 127~431VDC 90~305VAC, 127~431VDC 90~305VAC, 127~431VDC 90~305VAC, 127~431VDC 90~305VAC, 127~431VDC 90~305VAC, 127~431VDC 90~305VAC, 127VDC~431VDC 90~305VAC, 127VDC~431VDC 90~305VAC, 127VDC~431VDC 90~305VAC, 127VDC~431VDC
Output Current (A) 0~4.0 0~4.0 0~1.15 0~1.30 0~1.45 0~3.0 0~1.70 0~2.0 0~2.5 0~1.15 0~1.30 0~1.45 0~1.70 0~2.0 0~2.5 0~3.0 350mA 350mA 700mA 700mA
Output Voltage (V) 15 15 54 48 42 20 36 30 24 54 48 42 36 30 24 20 110 100~200 110
Output Voltage Options Single Single Single Single Single Single Single Single Single Single Single Single Single Single Single Single Single Single Single Single
Working Temperature -40~+70°C -40~+70°C -40°C~+70°C (Refer to "Derating Curve") -40°C~+70°C (Refer to "Derating Curve") -40°C~+70°C (Refer to "Derating Curve") -40~+70°C -40~+70°C -40~+70°C -40~+70°C -40~+50°C (refer to output derating curve) -40°C~+70°C (Refer to "Derating Curve") -40°C~+70°C (Refer to "Derating Curve") -40~+70°C -40~+70°C -40~+70°C -40~+70°C -40~+50°C (refer to output derating curve) -40~+50°C (refer to output derating curve) -40~+50°C (refer to output derating curve) -40~+50°C (refer to output derating curve)
Safety Standards UL8750, TUV EN61347-1, EN61347-2-13 approved; Design refer to UL60950-1, EN60950-1, EN60335-1 UL8750, TUV EN61347-1, EN61347-2-13 approved; Design refer to UL60950-1, EN60950-1, EN60335-1 UL8750, TUV EN61347-1, EN61347-2-13 approved; Design refer to UL60950-1, EN60950-1, EN60335-1 UL8750, TUV EN61347-1, EN61347-2-13 approved; Design refer to UL60950-1, EN60950-1, EN60335-1 UL8750, TUV EN61347-1, EN61347-2-13 approved; Design refer to UL60950-1, EN60950-1, EN60335-1 UL8750, TUV EN61347-1, EN61347-2-13 approved; Design refer to UL60950-1, EN60950-1, EN60335-1 UL8750, TUV EN61347-1, EN61347-2-13 approved; Design refer to UL60950-1, EN60950-1, EN60335-1 UL8750, TUV EN61347-1, EN61347-2-13 approved; Design refer to UL60950-1, EN60950-1, EN60335-1 UL8750, TUV EN61347-1, EN61347-2-13 approved; Design refer to UL60950-1, EN60950-1, EN60335-1 UL8750, TUV EN61347-1, EN61347-2-13 approved; Design refer to UL60950-1, EN60950-1, EN60335-1 UL8750, TUV EN61347-1, EN61347-2-13 approved; Design refer to UL60950-1, EN60950-1, EN60335-1 UL8750, TUV EN61347-1, EN61347-2-13 approved; Design refer to UL60950-1, EN60950-1, EN60335-1 UL8750, TUV EN61347-1, EN61347-2-13 approved; Design refer to UL60950-1, EN60950-1, EN60335-1 UL8750, TUV EN61347-1, EN61347-2-13 approved; Design refer to UL60950-1, EN60950-1, EN60335-1 UL8750, TUV EN61347-1, EN61347-2-13 approved; Design refer to UL60950-1, EN60950-1, EN60335-1 UL8750, TUV EN61347-1, EN61347-2-13 approved; Design refer to UL60950-1, EN60950-1, EN60335-1 UL8750, CSA C22.2 No. 250.0-08, EN61347-1, EN61347-2-13 independent, IP67 approved UL8750, CSA C22.2 No. 250.0-08, EN61347-1, EN61347-2-13 independent, IP65 approved UL8750, CSA C22.2 No. 250.0-08, EN61347-1, EN61347-2-13 independent, IP67 approved UL8750, CSA C22.2 No. 250.0-08, EN61347-1, EN61347-2-13 independent, IP65 approved
EMC Standards EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024 EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024 EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024 EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024 EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024 EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024 EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024 EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024 EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024 EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024 EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024 EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024 EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024 EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024 EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024 EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024 Compliance to EN55015, EN61000-3-2 Class C (¡Ù60% load) ; EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547, heavy industry level (surge L,N-FG: 4KV), criteria A Compliance to EN55015, EN61000-3-2 Class C (¡Ù60% load) ; EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547, heavy industry level (surge L,N-FG: 4KV), criteria A Compliance to EN55015, EN61000-3-2 Class C (¡Ù60% load) ; EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547, heavy industry level (surge L,N-FG: 4KV), criteria A Compliance to EN55015, EN61000-3-2 Class C (¡Ù60% load) ; EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547, heavy industry level (surge L,N-FG: 4KV), criteria A
Dimensions (LxWxH) mm 171x 61.5x 36.8 171x 61.5x 36.8 171x 61.5x 36.8 171x 61.5x 36.8
Packaging 20pcs/15.6Kg 20pcs/15.6Kg 20pcs/15.6Kg 20pcs/15.6Kg 20pcs/15.6Kg 20pcs/15.6Kg 20pcs/15.6Kg 20pcs/15.6Kg 20pcs/15.6Kg 20pcs/15.6Kg 20pcs/15.6Kg 20pcs/15.6Kg 20pcs/15.6Kg 20pcs/15.6Kg 20pcs/15.6Kg 20pcs/15.6Kg 20pcs/15.6Kg 20pcs/15.6Kg 20pcs/15.6Kg 20pcs/15.6Kg

Technical Specification

Download PDF Datasheet Mean Well LED Driver HLG-60H-C Series 70W 350mA – 700mA Specifications PDF
Wattage 70
Input Voltage (V) 90~305VAC, 127VDC~431VDC
Output Current (A) 700mA
Output Voltage (V) 110
Output Voltage Options Single
Working Temperature -40~+50°C (refer to output derating curve)
Safety Standards UL8750, CSA C22.2 No. 250.0-08, EN61347-1, EN61347-2-13 independent, IP67 approved
EMC Standards Compliance to EN55015, EN61000-3-2 Class C (¡Ù60% load) ; EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547, heavy industry level (surge L,N-FG: 4KV), criteria A
Dimensions (LxWxH) mm 171x 61.5x 36.8
Packaging 20pcs/15.6Kg

Write Your Own Review

Only registered users can write reviews. Please, log in or register