Mean Well LED Driver HLG-100H Series 96W 20V – 54V

Mean Well LED Driver HLG-100H Series 96W 20V – 54V

Be the first to review this product

Quick Overview

IP67 design for indoor or outdoor installations

Built-in active PFC, PF>0.9 for 60% of load or higher

5 years warranty

Protections: Short circuit / Over current / Over voltage / Over temperature

Other features:

  • Universal AC input (up to 305VAC) / Full range
  • High efficiency up to 94%
  • Output current adjustable through output cable or internal potentiometer
  • Cooling by free air convection
  • Suitable for dry, damp and wet location
  • Suitable for LED lighting and street lighting applications
  • Meet 4KV surge immunity level (IEC61000-4-5)
  • Class 2 power unit
  • IP67 rated and built-in 3 in 1 dimming function (1~10VDC, PWM signal, or resistance)

em-sample-alt

* Required Fields

TND32.11

Technical Specifications

HLG-100H-20AHLG-100H-24AHLG-100H-30AHLG-100H-36AHLG-100H-42AHLG-100H-48AHLG-100H-54AHLG-100H-20BHLG-100H-24BHLG-100H-30BHLG-100H-36BHLG-100H-42BHLG-100H-48BHLG-100H-54B
Wattage 96 96 96 96 96 96 96 96 96 96 96 96 96 96
Input Voltage (V) 90~305VAC, 127~431VDC 90~305VAC, 127~431VDC 90~305VAC, 127~431VDC 90~305VAC, 127~431VDC 90~305VAC, 127~431VDC 90~305VAC, 127~431VDC 90~305VAC, 127~431VDC 90~305VAC, 127~431VDC 90~305VAC, 127~431VDC 90~305VAC, 127~431VDC 90~305VAC, 127~431VDC 90~305VAC, 127~431VDC 90~305VAC, 127~431VDC 90~305VAC, 127~431VDC
Output Current (A) 0~4.8 0~4.0 0~3.2 0~2.65 0~2.28 0~4.8 0~1.77 0~4.8 0~4.0 0~3.2 0~2.65 0~2.28 0~2.0 0~1.77
Output Voltage (V) 20 24 30 36 42 48 54 20 24 30 36 42 48 54
Output Voltage Options Single Single Single Single Single Single Single Single Single Single Single Single Single Single
Working Temperature -40~+70°C (refer to output derating curve) -40~+70°C (refer to output derating curve) -40~+70°C (Refer to "Derating Curve") -40~+70°C (Refer to "Derating Curve") -40~+70°C (Refer to "Derating Curve") -40~+70°C (Refer to "Derating Curve") -40~+70°C (Refer to "Derating Curve") -40~+70°C (refer to output derating curve) -40~+70°C (Refer to "Derating Curve") -40~+70°C (Refer to "Derating Curve") -40~+70°C (Refer to "Derating Curve") -40~+70°C (Refer to "Derating Curve") -40~+70°C (Refer to "Derating Curve") -40~+70°C (Refer to "Derating Curve")
Safety Standards UL8750, TUV EN61347-1, EN61347-2-13, PSE J61347-2-13 approved; Design refer to UL60950-1, EN60950-1 UL8750, TUV EN61347-1, EN61347-2-13, PSE J61347-2-13 approved; Design refer to UL60950-1, EN60950-1 UL8750, TUV EN61347-1, EN61347-2-13, PSE J61347-2-13 approved; Design refer to UL60950-1, EN60950-1 UL8750, TUV EN61347-1, EN61347-2-13, PSE J61347-2-13 approved; Design refer to UL60950-1, EN60950-1 UL8750, TUV EN61347-1, EN61347-2-13, PSE J61347-2-13 approved; Design refer to UL60950-1, EN60950-1 UL8750, TUV EN61347-1, EN61347-2-13, PSE J61347-2-13 approved; Design refer to UL60950-1, EN60950-1 UL8750, TUV EN61347-1, EN61347-2-13, PSE J61347-2-13 approved; Design refer to UL60950-1, EN60950-1 UL8750, TUV EN61347-1, EN61347-2-13, PSE J61347-2-13 approved; Design refer to UL60950-1, EN60950-1 UL8750, TUV EN61347-1, EN61347-2-13, PSE J61347-2-13 approved; Design refer to UL60950-1, EN60950-1 UL8750, TUV EN61347-1, EN61347-2-13, PSE J61347-2-13 approved; Design refer to UL60950-1, EN60950-1 UL8750, TUV EN61347-1, EN61347-2-13, PSE J61347-2-13 approved; Design refer to UL60950-1, EN60950-1 UL8750, TUV EN61347-1, EN61347-2-13, PSE J61347-2-13 approved; Design refer to UL60950-1, EN60950-1 UL8750, TUV EN61347-1, EN61347-2-13, PSE J61347-2-13 approved; Design refer to UL60950-1, EN60950-1 UL8750, TUV EN61347-1, EN61347-2-13, PSE J61347-2-13 approved; Design refer to UL60950-1, EN60950-1
EMC Standards EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024 EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024 EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024 EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024 EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024 EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024 EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024 EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024 EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024 EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024 EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024 EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024 EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024 EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024
Packaging 16pcs/14.4Kg 12pcs/14.4Kg 12pcs/14.4Kg 12pcs/14.4Kg 12pcs/14.4Kg 12pcs/14.4Kg 12pcs/14.4Kg 12pcs/14.4Kg 12pcs/14.4Kg 12pcs/14.4Kg 12pcs/14.4Kg 12pcs/14.4Kg 12pcs/14.4Kg 12pcs/14.4Kg
RS Part No. 738-2328 738-2337 738-2330 738-2334 738-2343 738-2346 738-2340 721-1844 738-2337 738-2330 721-1850 721-1869 721-1862 721-1866

Technical Specification

Wattage 96
Input Voltage (V) 90~305VAC, 127~431VDC
Output Current (A) 0~1.77
Output Voltage (V) 54
Output Voltage Options Single
DC output adjustment N/A
Working Temperature -40~+70°C
Safety Standards UL8750, TUV EN61347-1, EN61347-2-13, PSE J61347-2-13 approved; Design refer to UL60950-1, EN60950-1
EMC Standards EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024
Dimensions (LxWxH) mm N/A
Packaging 12pcs/14.4Kg
RS Part No. 721-1866

Write Your Own Review